High Performance Dry Type Transformer for Enhanced Safety Standards

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • High Performance Dry Type Transformer for Enhanced Safety Standards
  • High Performance Dry Type Transformer for Enhanced Safety Standards
  • High Performance Dry Type Transformer for Enhanced Safety Standards
  • High Performance Dry Type Transformer for Enhanced Safety Standards
  • High Performance Dry Type Transformer for Enhanced Safety Standards
  • High Performance Dry Type Transformer for Enhanced Safety Standards
Find Similar Products

Basic Info.

Model NO.
SC(B)
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CE, ISO14001, ISO45001, ISO50001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
100-25000kVA
Primary Voltage
6/6.3/6.6/10/10.5/11/20/35kv
Secondary Voltage
11/10.5/6.3/6/3.15/0.4kv
Insulation Level
C, H, F
Frequency
50/60Hz
Impedance
4%/6%
Connection Symbol
Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Standard
IEC60076
Core Material
Silicon Steel
Cooling Way
an/Af
Working Temperature
-20ºC~60ºC
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
10000 Pieces/Year

Product Description

Pioneering excellence in China, the first company to achieve KEMA certification, passing the E2, C2, F1 tests for cast resin transformers, setting a benchmark in the industry.

CEEG's innovative cast resin dry type transformer is a marvel of engineering with numerous patents to its name. Specifically crafted for indoor environments requiring stringent fire and explosion protection, it offers unrivaled resilience to high temperatures and moisture. Ideal for commercial centers, residential complexes, hospitals, and industrial factories, this transformer is also adept for challenging outdoor environments such as petrochemical enterprises. Its superior ability to handle seasonal load variations and endure overload conditions makes it the prime choice for encapsulated distribution transformers, delivering unmatched performance.

Working Environment Specifications
Designed to operate effectively within temperatures ranging from -20ºC to 60ºC;

Insulation

Material

expoxy resin class H / class C Nomex paper

Structure

 

HV coil is multi layer sectional cylinder structure, LV coil is foil with longitudinal air chamber structure.

Reliability

Insulation class

H(180ºC)

Tem. rise of coil

125K(normal 100K)

Over-load capacity

continuously 120%

Cooling method

AN/AF

 Environmental Protection

Noise

Low

Recycling

easy recycling and low pollution



Distinguished Product Features

1. Exceptionally reliable with minimal losses, featuring low partial discharge (less than 5PC), low operational noise, and exceptional heat dissipation capabilities, engineered to handle up to 150% overload in forced air cooling scenarios.

2. Superb moisture resistance, enabling flawless operation in environments with up to 100% humidity.

3. Ensures safety with fire-protection and pollution-free operations, perfectly designed for direct installation in load centers.

4. Integrated with an advanced temperature protection and control system for optimal functionality.

5. Maintenance-free design that is easy to install and operates economically with low costs.



Remarkable Export Case
Since 2014, we've been a trusted supplier of CEEG SCB and SC series cast resin dry-type transformers to LafargeHolcim, a partnership that stands strong today. These transformers have demonstrated their excellence in performance at LafargeHolcim's cement plants located in Nigeria, the Philippines, and Cameroon.


High Performance Dry Type Transformer for Enhanced Safety Standards
High Performance Dry Type Transformer for Enhanced Safety Standards
 

Class F Insulation SCB10-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB10-315/10

4

880

3470

1.0

55

660 x 660

SCB10-400/10

4

980

3990

1.0

55

660 x 660

SCB10-500/10

4

1160

4880

1.0

57

660 x 660

SCB10-630/10

4

1340

5880

0.85

57

820 x 820

SCB10-630/10

6

1300

5960

0.85

57

820 x 820

SCB10-800/10

6

1520

6960

0.85

58

820 x 820

SCB10-1000/10

6

1770

8130

0.85

58

820 x 820

SCB10-1250/10

6

2090

9690

0.85

60

820 x 820

SCB10-1600/10

6

2450

11700

0.85

60

820 x 820

SCB10-2000/10

6

3050

14400

0.70

62

820 x 820

SCB10-2500/10

6

3600

17100

0.70

62

820 x 820

 

Class F Insulation SCB11-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB11-315/10

4

790

3470

1.0

55

660 x 660

SCB11-400/10

4

880

3990

1.0

55

660 x 660

SCB11-500/10

4

1040

4880

1.0

57

660 x 660

SCB11-630/10

4

1200

5880

0.85

57

820 x 820

SCB11-630/10

6

1170

5960

0.85

57

820 x 820

SCB11-800/10

6

1360

6960

0.85

58

820 x 820

SCB11-1000/10

6

1590

8130

0.85

58

820 x 820

SCB11-1250/10

6

1880

9690

0.85

60

820 x 820

SCB11-1600/10

6

2200

11700

0.85

60

820 x 820

SCB11-2000/10

6

2740

14400

0.70

62

820 x 820

SCB11-2500/10

6

3240

17100

0.70

62

820 x 820

 

Class F Insulation SCB12-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB12-315/10

4

705

3470

1.0

55

660 x 660

SCB12-400/10

4

785

3990

1.0

55

660 x 660

SCB12-500/10

4

930

4880

1.0

57

660 x 660

SCB12-630/10

4

1070

5880

0.85

57

820 x 820

SCB12-630/10

6

1040

5960

0.85

57

820 x 820

SCB12-800/10

6

1210

6960

0.85

58

820 x 820

SCB12-1000/10

6

1410

8130

0.85

58

820 x 820

SCB12-1250/10

6

1670

9690

0.85

60

820 x 820

SCB12-1600/10

6

1960

11700

0.85

60

820 x 820

SCB12-2000/10

6

2440

14400

0.70

62

820 x 820

SCB12-2500/10

6

2880

17100

0.70

62

820 x 820



High Performance Dry Type Transformer for Enhanced Safety StandardsHigh Performance Dry Type Transformer for Enhanced Safety StandardsHigh Performance Dry Type Transformer for Enhanced Safety Standards

Advanced Equipment:


State-of-the-art Slitting Line

High Performance Dry Type Transformer for Enhanced Safety Standards

Precision Shearing Line
High Performance Dry Type Transformer for Enhanced Safety Standards

HEDRICH Vacuum Casting Tank for superior casting quality
High Performance Dry Type Transformer for Enhanced Safety Standards

Efficient Curing Oven
High Performance Dry Type Transformer for Enhanced Safety Standards

Innovative Foil Winding technology
High Performance Dry Type Transformer for Enhanced Safety Standards

Comprehensive Testing Center for quality assurance
High Performance Dry Type Transformer for Enhanced Safety Standards
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now