Introducing the CEEG compact substation, a marvel of engineering that seamlessly integrates high-voltage switchgear, distribution transformer, and low-voltage switchgear into a unified powerhouse. Designed for versatile use, both indoors and outdoors, this packaged substation boasts remarkable integration, occupying minimal space while promising low investment and hassle-free installation and maintenance. Operating at rated voltages of 6KV, 10KV, and 35KV, its enclosure is fortified with protection ratings of IP54 and IP33. Custom solutions are readily available to meet specialized requirements, ensuring that our innovation caters to your unique needs.
No. | Items | Unit | HV Switchgear | Transformer | LV Switchgear |
1 | Rated Voltage | kV | 10.5 | 10.5/0.4 | 0.4/0.23 |
2 | Rated Capacity | kVA | \ | 800 | |
3 | Rated Current | A | 20-200 | 100-4000 | |
4 | Short Circuit Interrupting Current | kA | 31.5,50 | \ | 30-50 |
5 | Short Circuit Makring Current | kA | 50 | \ | |
6 | Dynamic Stable Current | kA | \ | \ | |
7 | Thermal Stable Current | kA/S | 10-20kA/4s | \ | 15~65x1 |
8 | PFWV Between Phases, to earth/isolation contacts | kV/min | 42 | 35 | 2.5~2 |
9 | Lightning Strike (full-wave) | kV | 75/85 | \ | \ |
10 | Housing Proof Class | IP43 | |||
11 | Sound Level | dB | <55 |
Product Features
Unmatched Production Performance: Our substation's frame is meticulously coated with a specialized paint layer, enhancing its durability and performance. Ingeniously designed internal safeguards are incorporated to prevent:
Erroneous operation of circuit breakers, ensuring safety and reliability.
Operating isolators under load conditions, maintaining optimal functionality.
Engaging grounding wires or switches while energized, safeguarding against mishaps.
Activating circuit breakers with grounding wires in position, minimizing operational risks.
Inadvertent entry into live compartments, fortifying user safety.
Engineered with BIOSCO technology, its modular structure simplifies installation and operation, offering seamless functionality.
Constructed using premium welded structural steel, it delivers superior mechanical strength and possesses a surface meticulously treated for robust weather resistance.
Innovative Environmental Management: The integration of automatic temperature control devices in the transformer and low-voltage rooms ensures precise temperature regulation and efficient ventilation, adapting to environmental changes effortlessly.
The advanced top insulation layer effectively prevents condensation due to sudden temperature fluctuations, with the option for additional insulation around the enclosure for enhanced protection.
Intelligent Operations: Designed for the future, equipped with smart operation and maintenance functionalities, including intelligent data collection and analysis on high-voltage and low-voltage switchgear and the transformer, ensuring optimal performance and efficiency.
Design and Customization: Our substations not only promise functionality but also captivate with their aesthetic appeal. With customizable features and a plethora of choices, the internal structure is available in 'H' and 'T' shapes, offering configurations with both corridor and non-corridor layouts to cater to diverse spatial and operational needs.
Enclosure Structure
High Voltage Chamber:
Within the high voltage chamber lies a robust high-voltage ring main unit, featuring high-voltage switches compatible with sulfur hexafluoride load switches and vacuum circuit breakers. The high-voltage cabinet is designed to shield the transformer from short circuits and overloads, ensuring maximum protection and efficiency.
Transformer Chamber:
Our transformer chamber accommodates either dry-type or liquid (oil) immersed transformers, equipped with an advanced ventilation system that boasts adjustable temperature settings. It features live space barriers to prevent accidental contact during observation, prioritizing safety and operational continuity.
Low Voltage Chamber:
The secondary low voltage chamber, offered in configurations with or without a corridor, is engineered to house an array of essential components such as metering cabinets, main incoming cabinets, outgoing cabinets, capacitor cabinets, and interlocking cabinets for dual transformers. It delivers comprehensive functionality, with capacitive reactive power compensation ranging from 15% to 30% of the transformer capacity, ensuring efficiency and reliability.
Operating Environment
Expertly designed to operate within an ambient temperature range of -25°C to 40°C, promising adaptability and resilience in various climates.
Functioning optimally at altitudes not exceeding 1000 meters, ensuring reliable performance across diverse geographical locations.
Designed to withstand relative humidity levels of up to 90% at 25°C, with the capacity to endure short-term peaks up to 100%, making it ideal for humid environments.
Installation is suited for environments devoid of fire, explosion hazards, chemical corrosion, or severe vibrations, ensuring safe and stable operations.