Durable Epoxy Resin Transformer for Industrial Applications

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Durable Epoxy Resin Transformer for Industrial Applications
  • Durable Epoxy Resin Transformer for Industrial Applications
  • Durable Epoxy Resin Transformer for Industrial Applications
  • Durable Epoxy Resin Transformer for Industrial Applications
  • Durable Epoxy Resin Transformer for Industrial Applications
  • Durable Epoxy Resin Transformer for Industrial Applications
Find Similar Products

Basic Info.

Model NO.
SC(B)
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CE, ISO14001, ISO45001, ISO50001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
100-25000kVA
Primary Voltage
6/6.3/6.6/10/10.5/11/20/35kv
Secondary Voltage
11/10.5/6.3/6/3.15/0.4kv
Insulation Level
C, H, F
Frequency
50/60Hz
Impedance
4%/6%
Connection Symbol
Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Standard
IEC60076
Core Material
Silicon Steel
Cooling Way
an/Af
Working Temperature
-20ºC~60ºC
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
10000 Pieces/Year

Product Description

Proudly the pioneering company in China to achieve the prestigious KEMA E2, C2, F1 certifications for our state-of-the-art cast resin transformers, a testament to our commitment to excellence.

CEEG's advanced cast resin dry-type transformer is a marvel of innovation, protected by numerous patents. This exceptional product is perfectly engineered for indoor environments where fire and explosion safety, as well as resilience to high temperatures and humidity, are paramount-such as bustling commercial centers, serene residential areas, critical hospitals, and bustling factories. Our vacuum cast coil transformer not only meets but exceeds stringent standards for specialized outdoor conditions, including the demanding environments of petrochemical enterprises. Its remarkable adaptability to seasonal load changes and overload conditions makes it a top-tier choice for encapsulated distribution transformers.

Optimal Working Environment
Operates efficiently within a temperature range of -20ºC to 60ºC;

Insulation

Material

expoxy resin class H / class C Nomex paper

Structure

 

HV coil is multi layer sectional cylinder structure, LV coil is foil with longitudinal air chamber structure.

Reliability

Insulation class

H(180ºC)

Tem. rise of coil

125K(normal 100K)

Over-load capacity

continuously 120%

Cooling method

AN/AF

 Environmental Protection

Noise

Low

Recycling

easy recycling and low pollution



Distinctive Product Features

1. Exceptionally reliable with remarkably low loss, minimal partial discharge (under 5PC), minimal noise output, and outstanding heat dissipation capability, designed to endure a 150% overload when under forced air cooling conditions.

2. Superior moisture resistance, engineered for flawless operation even in environments with 100% humidity.

3. Unmatched safety features, ensuring fire protection and eco-friendly operation, making them perfect for direct installation in load centers.

4. Integrated with an advanced temperature protection and control system for optimal performance.

5. Designed for minimal maintenance, ensuring effortless installation and delivering low total operational costs.



Noteworthy Export Case
Since 2014, we have proudly supplied the CEEG SCB and SC series of cast resin dry-type transformers to LafargeHolcim, fostering a lasting partnership. These transformers are successfully installed and have demonstrated exceptional performance within LafargeHolcim's cement plants located in Nigeria, the Philippines, and Cameroon.


Durable Epoxy Resin Transformer for Industrial Applications
Durable Epoxy Resin Transformer for Industrial Applications
 

Class F Insulation SCB10-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB10-315/10

4

880

3470

1.0

55

660 x 660

SCB10-400/10

4

980

3990

1.0

55

660 x 660

SCB10-500/10

4

1160

4880

1.0

57

660 x 660

SCB10-630/10

4

1340

5880

0.85

57

820 x 820

SCB10-630/10

6

1300

5960

0.85

57

820 x 820

SCB10-800/10

6

1520

6960

0.85

58

820 x 820

SCB10-1000/10

6

1770

8130

0.85

58

820 x 820

SCB10-1250/10

6

2090

9690

0.85

60

820 x 820

SCB10-1600/10

6

2450

11700

0.85

60

820 x 820

SCB10-2000/10

6

3050

14400

0.70

62

820 x 820

SCB10-2500/10

6

3600

17100

0.70

62

820 x 820

 

Class F Insulation SCB11-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB11-315/10

4

790

3470

1.0

55

660 x 660

SCB11-400/10

4

880

3990

1.0

55

660 x 660

SCB11-500/10

4

1040

4880

1.0

57

660 x 660

SCB11-630/10

4

1200

5880

0.85

57

820 x 820

SCB11-630/10

6

1170

5960

0.85

57

820 x 820

SCB11-800/10

6

1360

6960

0.85

58

820 x 820

SCB11-1000/10

6

1590

8130

0.85

58

820 x 820

SCB11-1250/10

6

1880

9690

0.85

60

820 x 820

SCB11-1600/10

6

2200

11700

0.85

60

820 x 820

SCB11-2000/10

6

2740

14400

0.70

62

820 x 820

SCB11-2500/10

6

3240

17100

0.70

62

820 x 820

 

Class F Insulation SCB12-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB12-315/10

4

705

3470

1.0

55

660 x 660

SCB12-400/10

4

785

3990

1.0

55

660 x 660

SCB12-500/10

4

930

4880

1.0

57

660 x 660

SCB12-630/10

4

1070

5880

0.85

57

820 x 820

SCB12-630/10

6

1040

5960

0.85

57

820 x 820

SCB12-800/10

6

1210

6960

0.85

58

820 x 820

SCB12-1000/10

6

1410

8130

0.85

58

820 x 820

SCB12-1250/10

6

1670

9690

0.85

60

820 x 820

SCB12-1600/10

6

1960

11700

0.85

60

820 x 820

SCB12-2000/10

6

2440

14400

0.70

62

820 x 820

SCB12-2500/10

6

2880

17100

0.70

62

820 x 820



Durable Epoxy Resin Transformer for Industrial ApplicationsDurable Epoxy Resin Transformer for Industrial ApplicationsDurable Epoxy Resin Transformer for Industrial Applications

Sophisticated Equipment:


Precision Slitting Line

Durable Epoxy Resin Transformer for Industrial Applications

Efficient Shearing Line
Durable Epoxy Resin Transformer for Industrial Applications

HEDRICH Vacuum Casting Tank for superior quality
Durable Epoxy Resin Transformer for Industrial Applications

High-Performance Curing Oven
Durable Epoxy Resin Transformer for Industrial Applications

Advanced Foil Winding
Durable Epoxy Resin Transformer for Industrial Applications

State-of-the-art Testing Center
Durable Epoxy Resin Transformer for Industrial Applications
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now