Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
  • Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
  • Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
  • Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
  • Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
  • Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
Find Similar Products

Basic Info.

Model NO.
PSCD/PSCBFD/PSGBFD
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CE, ISO14001, ISO45001, ISO50001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
100-8000kVA
Primary Voltage
6/6.3/6.6/10/10.5/11kv
Secondary Voltage
0.4/0.45kv
Frequency
50/60Hz
Impedance
4%//6%/7.5%/8%/9%
Connection Symbol
: Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
20

Product Description

Introducing the Marine (Ocean Platform) Transformer: A Revolutionary Solution for Safer and More Efficient Maritime Power Management.
Our transformers are expertly engineered with a range of insulation classes, including B, F, and H, ensuring durability and reliability. The low-voltage transformers, designed for applications below 1kV, offer a robust capacity of up to 8000kVA. Similarly, our medium-voltage transformers, ideal for vessels, ships, and offshore platforms operating below 10kV, also support capacities up to 8000kVA. We tailor our designs to meet unique requirements and proudly supply product certifications from globally recognized classification societies such as CCS, ABS, BV, DNVGL, LR, KR, NK, RINA, and others.

Exceptional Structural Features of the Product
Our core material is crafted from superior quality cold-rolled silicon steel sheets, meticulously laminated at a precise 45° diagonal angle, ensuring both strength and efficiency.

The insulation materials utilized in our transformers are of Class B, F, or H NOMEX paper, contributing to an impressive service life exceeding 30 years.

Engineered for Resistance: Our transformers boast outstanding moisture, salt spray, mold, and rust resistance, with the iron core surface coated in a unique protective resin.

Engineered for Superior Performance: Experience low losses, minimal partial discharge, a robust overload capacity, and reduced noise. Our iron core materials, made from 0.18-0.3mm thick, highly permeable, high-quality grain-oriented cold-rolled silicon steel sheets, minimize loss. The through-bolt structure plays a critical role in significantly diminishing noise levels.

For the marine transformers, the coil features a non-closure structure. In contrast, the ocean platform transformers use a stuffed epoxy resin casting, ensuring exceptional flame retardation properties.

Our transformers are housed in cases constructed from high-quality steel sheets with protection classes including IP00, IP20, IP22, and IP23.

The innovative design includes a strategically placed stuffing box, located either on the left or right of the case's top, with a bottom in/bottom out wiring style for capacities of 500 kVA and above. Cable holes are thoughtfully positioned on the transformer's base, equipped with a scratch-proof and fixation device for enhanced protection.

Optimal Application Conditions for Our Transformers
Our company's products are engineered to operate seamlessly under the following conditions:
Ambient temperature range: -25°C to 45°C, ensuring functionality in diverse climates.
Capable of withstanding relative humidity levels of up to 95%, demonstrating superior adaptability.
Designed to endure vibration and shock intrinsic to the installation environment, providing consistent performance.
Suitable for operations with swing angles up to 22.5° and inclining angles up to 15°, ensuring stability and reliability.
Durable enough to resist the effects of dew, oil mist, salt mist, and molds.


Comprehensive Technical Data for Ocean Platform Transformers

Type

Rated Capacity

(kVA)

Primary

Voltage

(kV)

Secondary

Voltage

(kV)

Tapping Range

Vector Group

No-load Loss

(W)

Load Loss

(W)

75°C

No-load

Current

(%)

Impedance

(%)

75°C

PSCD-100/10

100

11

10.5

10

6.6

6.3

6.0

3.3

3.0

0.45

0.4

±2×2.5%

±5%

Dyn11

500

1850

2.4

4

PSCD-125/10

125

590

2170

2.2

PSCD-160/10

160

680

2500

2.2

PSCD-200/10

200

780

2970

2.0

PSCD-250/10

250

900

3240

2.0

PSCD-315/10

315

1100

4080

1.8

PSCD-400/10

400

1220

4690

1.8

PSCD-500/10

500

1450

5740

1.8

PSCBFD-630/10

630

1620

7010

1.6

6

PSCBFD-800/10

800

1900

8180

1.6

PSCBFD-1000/10

1000

2210

9560

1.4

PSCBFD-1250/10

1250

2610

11400

1.4

PSCBFD-1600/10

1600

3060

13800

1.4

PSCBFD-2000/10

2000

4150

17000

1.2

PSCBFD-2500/10

2500

5000

20200

1.2

PSCBFD-3150/10

3150

5400

24000

1

PSCBFD-3500/10

3500

5800

28000

1

7.5

PSGBFD-4000/10

4000

6500

34000

0.8

8

PSGBFD-5000/10

5000

7800

42000

0.8

PSGBFD-6300/10

6300

8960

47000

0.6

PSGBFD-8000/10

8000

10220

53000

0.6

9

Please Note: All technical data provided herein serves as a reference. We reserve the right to make changes without prior notification to ensure the highest standards and compliance.

Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv

Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv

Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv
Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kv


Saltwater Resistant Transformer for Ships, Primary Voltage 6.6kvSaltwater Resistant Transformer for Ships, Primary Voltage 6.6kv

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now