Cast Resin Dry Type Transformer Conforms with IEC60076

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Cast Resin Dry Type Transformer Conforms with IEC60076
  • Cast Resin Dry Type Transformer Conforms with IEC60076
  • Cast Resin Dry Type Transformer Conforms with IEC60076
  • Cast Resin Dry Type Transformer Conforms with IEC60076
  • Cast Resin Dry Type Transformer Conforms with IEC60076
  • Cast Resin Dry Type Transformer Conforms with IEC60076
Find Similar Products

Basic Info.

Model NO.
SC(B)
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CE, ISO14001, ISO45001, ISO50001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
100-25000kVA
Primary Voltage
6/6.3/6.6/10/10.5/11/20/35kv
Secondary Voltage
11/10.5/6.3/6/3.15/0.4kv
Insulation Level
C, H, F
Frequency
50/60Hz
Impedance
4%/6%
Connection Symbol
Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Standard
IEC60076
Core Material
Silicon Steel
Cooling Way
an/Af
Working Temperature
-20ºC~60ºC
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
10000 Pieces/Year

Product Description

Trailblazers in the Chinese industry, we proudly stand as the first company to successfully pass the prestigious KEMA E2, C2, F1 tests for cast resin transformers, setting a new benchmark for excellence.

CEEG's cast resin dry-type transformer is an engineering marvel holding multiple patents. This product is perfectly crafted for indoor environments requiring top-tier fire and explosion protection, as well as exceptional resilience to high temperatures and moisture. Ideal for places like bustling commercial centers, serene residential zones, vital hospitals, and dynamic factories, our transformers are also designed to excel in stringent outdoor settings, including challenging petrochemical enterprises. With outstanding adaptability to seasonal load changes and superior performance during overload conditions, it becomes the quintessential choice for encapsulated distribution transformers.

Optimal Working Environment Details
Our transformers thrive in a wide working temperature range of -20ºC to 60ºC, ensuring reliable performance across diverse climates.

Insulation

Material

expoxy resin class H / class C Nomex paper

Structure

 

HV coil is multi layer sectional cylinder structure, LV coil is foil with longitudinal air chamber structure.

Reliability

Insulation class

H(180ºC)

Tem. rise of coil

125K(normal 100K)

Over-load capacity

continuously 120%

Cooling method

AN/AF

 Environmental Protection

Noise

Low

Recycling

easy recycling and low pollution



Exceptional Product Features

1. Unmatched reliability with minimal loss, ultra-low partial discharge (below 5PC,) exceptionally low noise, and superior heat dissipation capabilities, all while enduring up to 150% overload under forced air cooling conditions.

2. Remarkable moisture-resistant properties enable it to function seamlessly even in environments with 100% humidity.

3. Ensuring utmost safety, our transformers offer fire protection and pollution-free operation, making them perfect for direct deployment in load centers.

4. Integrated with a state-of-the-art temperature protection and control system for optimal safety and performance.

5. Designed to be maintenance-free, these transformers are easy to install and ensure low overall operating costs.



Prestigious Export Case
Since 2014, we have been proudly supplying our CEEG SCB and SC series of cast resin dry-type transformers to LafargeHolcim. This enduring partnership has seen our transformers being efficiently installed and operated in LafargeHolcim's cement plants located in Nigeria, the Philippines, and Cameroon, exemplifying global trust in our products.


Cast Resin Dry Type Transformer Conforms with IEC60076
Cast Resin Dry Type Transformer Conforms with IEC60076
 

Class F Insulation SCB10-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB10-315/10

4

880

3470

1.0

55

660 x 660

SCB10-400/10

4

980

3990

1.0

55

660 x 660

SCB10-500/10

4

1160

4880

1.0

57

660 x 660

SCB10-630/10

4

1340

5880

0.85

57

820 x 820

SCB10-630/10

6

1300

5960

0.85

57

820 x 820

SCB10-800/10

6

1520

6960

0.85

58

820 x 820

SCB10-1000/10

6

1770

8130

0.85

58

820 x 820

SCB10-1250/10

6

2090

9690

0.85

60

820 x 820

SCB10-1600/10

6

2450

11700

0.85

60

820 x 820

SCB10-2000/10

6

3050

14400

0.70

62

820 x 820

SCB10-2500/10

6

3600

17100

0.70

62

820 x 820

 

Class F Insulation SCB11-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB11-315/10

4

790

3470

1.0

55

660 x 660

SCB11-400/10

4

880

3990

1.0

55

660 x 660

SCB11-500/10

4

1040

4880

1.0

57

660 x 660

SCB11-630/10

4

1200

5880

0.85

57

820 x 820

SCB11-630/10

6

1170

5960

0.85

57

820 x 820

SCB11-800/10

6

1360

6960

0.85

58

820 x 820

SCB11-1000/10

6

1590

8130

0.85

58

820 x 820

SCB11-1250/10

6

1880

9690

0.85

60

820 x 820

SCB11-1600/10

6

2200

11700

0.85

60

820 x 820

SCB11-2000/10

6

2740

14400

0.70

62

820 x 820

SCB11-2500/10

6

3240

17100

0.70

62

820 x 820

 

Class F Insulation SCB12-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB12-315/10

4

705

3470

1.0

55

660 x 660

SCB12-400/10

4

785

3990

1.0

55

660 x 660

SCB12-500/10

4

930

4880

1.0

57

660 x 660

SCB12-630/10

4

1070

5880

0.85

57

820 x 820

SCB12-630/10

6

1040

5960

0.85

57

820 x 820

SCB12-800/10

6

1210

6960

0.85

58

820 x 820

SCB12-1000/10

6

1410

8130

0.85

58

820 x 820

SCB12-1250/10

6

1670

9690

0.85

60

820 x 820

SCB12-1600/10

6

1960

11700

0.85

60

820 x 820

SCB12-2000/10

6

2440

14400

0.70

62

820 x 820

SCB12-2500/10

6

2880

17100

0.70

62

820 x 820



Cast Resin Dry Type Transformer Conforms with IEC60076Cast Resin Dry Type Transformer Conforms with IEC60076Cast Resin Dry Type Transformer Conforms with IEC60076

Advanced Equipment Utilized:


Our state-of-the-art Slitting Line,

Cast Resin Dry Type Transformer Conforms with IEC60076

precision Shearing Line,
Cast Resin Dry Type Transformer Conforms with IEC60076

cutting-edge HEDRICH Vacuum Casting Tank,
Cast Resin Dry Type Transformer Conforms with IEC60076

high-efficiency Curing Oven,
Cast Resin Dry Type Transformer Conforms with IEC60076

innovative Foil Winding technology,
Cast Resin Dry Type Transformer Conforms with IEC60076

and comprehensive Testing Center ensure exceptional product quality and performance.
Cast Resin Dry Type Transformer Conforms with IEC60076
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now