Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
  • Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
  • Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
  • Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
  • Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
  • Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
Find Similar Products

Basic Info.

Model NO.
SC(B)
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CE, ISO14001, ISO45001, ISO50001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
100-25000kVA
Primary Voltage
6/6.3/6.6/10/10.5/11/20/35kv
Secondary Voltage
11/10.5/6.3/6/3.15/0.4kv
Insulation Level
C, H, F
Frequency
50/60Hz
Impedance
4%/6%
Connection Symbol
Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Standard
IEC60076
Core Material
Silicon Steel
Cooling Way
an/Af
Working Temperature
-20ºC~60ºC
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
10000 Pieces/Year

Product Description

China Electric Equipment (Jiangsu) Transformer Manufacture Co., Ltd. takes immense pride as the pioneering company in China to triumphantly pass the rigorous KEMA E2, C2, F1 tests for our exceptional cast resin transformer.

CEEG's innovative cast resin try type transformer, a hallmark of cutting-edge technology, is fortified with numerous patents. This remarkable product is meticulously engineered for indoor settings that require unparalleled fire and explosion protection, as well as outstanding resilience to high temperature and moisture. It is ideally suited for commercial centers, residential areas, hospitals, and factories, ensuring safety and reliability. Moreover, our vacuum cast coil transformer adheres to the stringent standards necessary for challenging outdoor environments, such as those found in petrochemical enterprises. Its exceptional adaptability to seasonal load variations and overload conditions emphasizes its superiority, making it the optimal choice for encapsulated distribution transformers.

Working Environment
This transformer exhibits an impressive working temperature range: -20ºC to 60ºC;

Insulation

Material

expoxy resin class H / class C Nomex paper

Structure

 

HV coil is multi layer sectional cylinder structure, LV coil is foil with longitudinal air chamber structure.

Reliability

Insulation class

H(180ºC)

Tem. rise of coil

125K(normal 100K)

Over-load capacity

continuously 120%

Cooling method

AN/AF

 Environmental Protection

Noise

Low

Recycling

easy recycling and low pollution



Product Features

1. Our transformers are highly reliable, featuring low loss and exceptionally low partial discharge (below 5PC), along with low noise levels and robust heat dissipation capacity. They boast an impressive ability to endure 150% overload in forced air cooling conditions.

2. They offer outstanding moisture-resistant performance, capable of seamless operation even in 100% humidity conditions.

3. Designed for utmost safety, fire protection, and pollution-free operation, they are perfectly suited for direct installation in load centers.

4. Equipped with an advanced comprehensive temperature protection and control system, ensuring precision and safety.

5. Our transformers are maintenance-free, incredibly easy to install, and deliver low overall operating costs, offering a worry-free experience.



Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
 

Class F Insulation SCB10-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB10-315/10

4

880

3470

1.0

55

660 x 660

SCB10-400/10

4

980

3990

1.0

55

660 x 660

SCB10-500/10

4

1160

4880

1.0

57

660 x 660

SCB10-630/10

4

1340

5880

0.85

57

820 x 820

SCB10-630/10

6

1300

5960

0.85

57

820 x 820

SCB10-800/10

6

1520

6960

0.85

58

820 x 820

SCB10-1000/10

6

1770

8130

0.85

58

820 x 820

SCB10-1250/10

6

2090

9690

0.85

60

820 x 820

SCB10-1600/10

6

2450

11700

0.85

60

820 x 820

SCB10-2000/10

6

3050

14400

0.70

62

820 x 820

SCB10-2500/10

6

3600

17100

0.70

62

820 x 820

 

Class F Insulation SCB11-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB11-315/10

4

790

3470

1.0

55

660 x 660

SCB11-400/10

4

880

3990

1.0

55

660 x 660

SCB11-500/10

4

1040

4880

1.0

57

660 x 660

SCB11-630/10

4

1200

5880

0.85

57

820 x 820

SCB11-630/10

6

1170

5960

0.85

57

820 x 820

SCB11-800/10

6

1360

6960

0.85

58

820 x 820

SCB11-1000/10

6

1590

8130

0.85

58

820 x 820

SCB11-1250/10

6

1880

9690

0.85

60

820 x 820

SCB11-1600/10

6

2200

11700

0.85

60

820 x 820

SCB11-2000/10

6

2740

14400

0.70

62

820 x 820

SCB11-2500/10

6

3240

17100

0.70

62

820 x 820

 

Class F Insulation SCB12-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB12-315/10

4

705

3470

1.0

55

660 x 660

SCB12-400/10

4

785

3990

1.0

55

660 x 660

SCB12-500/10

4

930

4880

1.0

57

660 x 660

SCB12-630/10

4

1070

5880

0.85

57

820 x 820

SCB12-630/10

6

1040

5960

0.85

57

820 x 820

SCB12-800/10

6

1210

6960

0.85

58

820 x 820

SCB12-1000/10

6

1410

8130

0.85

58

820 x 820

SCB12-1250/10

6

1670

9690

0.85

60

820 x 820

SCB12-1600/10

6

1960

11700

0.85

60

820 x 820

SCB12-2000/10

6

2440

14400

0.70

62

820 x 820

SCB12-2500/10

6

2880

17100

0.70

62

820 x 820



Advanced Distribution Transformer with Low Loss for Optimal Energy EfficiencyAdvanced Distribution Transformer with Low Loss for Optimal Energy EfficiencyAdvanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

State-of-the-Art Equipment:


Slitting Line

Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

Shearing Line
Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

HEDRICH Vacuum Casting Tank
Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

Curing Oven
Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

Foil Winding
Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency

Comprehensive Testing Center
Advanced Distribution Transformer with Low Loss for Optimal Energy Efficiency
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now