S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
  • S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
  • S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
  • S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
  • S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
  • S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
Find Similar Products

Basic Info.

Model NO.
S11-1250/11
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
1250kVA
Primary Voltage
6/6.3/6.6/10/10.5/11kv
Secondary Voltage
0.4kv
Frequency
50/60Hz
Impedance
4%/4.5%
Connection Symbol
Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
20

Product Description

Brief Introduction

This series product possesses FOUR LOW AND ONE HIGH characteristics which are: low loss, low noisy, low temperature rising, low partial discharge and high reliability, as well as core-hoisting free and no leakage. With the approval of National Transformer Quality Inspection and Testing Center, all the index of the transformer achieve JB/T3837-2003 standard.

Model

S  F  Z  10-×××/××

S/N Symbol Meaning
1 S Three phases
2 F Air-cooling(blank for Natural cooling)
3 Z On load tap changing(bland for no-load tap changing)
4 10 Symbol of Performance level
5 xxx Rated capacity,kVA
6 xx Voltage grade of HV winding,kV


Features 

1.    Scientific and advanced design scheme

By using computer software to analysis the winding electric field under high voltage, it can calculate the exact distributing of winding electric field grads and then to make sure the winding structure can meet the impulse under high voltage. Analyzing and calculating the insulation structure of transformer and using the scientific insulation structure to ensure the products operate safely. Analyzing and calculating the magnetic leakage and temperature field to ensure the field performance accordance to the design demand. Optimizing the lamination design to minimize the magnetic distortion in the gap and to enhance the no-load performance.

2.    Iron Cores

The iron core adopts high quality grain-oriented cold-rolled silicon-steel sheet, and cut by special shearing machine which result in just tiny burr. The application of multi-steps and 45°all-leaning joints lows the no-load loss,  no-load current and noise efficiently. The core clamping device adopts board structure which result in high mechanical intensity. Fasten nails can ensure the enough transformer axis padding block pressure.

3.    High purity oxygen free cooper windings, reduce the load loss

Inner coil was wound directly on the insulation barrel, where chamfering spacers and padding blocks are applied to uniform the electric field and enhance stability. And, BDK-80M synchronized lifting up equipment was applied in assembly to ensure the axial location of the windings and reinforce the axial strength.

4. Tank

Wide-width steel plate is adopted to reduce welding seams on the flat roof, folded plate type tank, it has concise and dedicate appearance and also high mechanical strength which passed the standard positive pressure and vacuum test. In addition, special welding technology and groove type flange ensure the tank and the pipes are able of long time use without leakage. Wide plate radiation system equipped with heavy duty and low noise blowers rises up the heat dissipating center, improve the efficiency, reduce radiating plates and prevent leakage. It can be directly mounted on the transformer. And capsule type conservator can effectively delay the aging of the oil what is implanted in under vacuum condition to reinforce the electric strength.

5. Protection System

Pt100 thermal resistors temperature control system is generally applied in the transformer body, pressure relief valve with contacts is equipped on the top of tank, oil indicator with contact and vacuum relays are equipped on the conservator, and as well, the oil pressure indicator with contacts is equipped in the tank. All this equipments can be applied for signal conversion and transfer. Both HV and LV bushings are pollution retardant porcelain oil type, which can lengthen the insulation space and be applied in high pollution condition. Padding plates and terminal case are made of stainless steel to make elegant appearance.

S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer
S11-1250/11 11kv 1250kVA Oil-Immersed Distribution Transformer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now