Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
to see all verified strength labels (30)
  • Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
  • Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
  • Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
  • Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
  • Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
  • Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
Find Similar Products

Basic Info.

Model NO.
SC(B)
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CE, ISO14001, ISO45001, ISO50001
Usage
Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
100-25000kVA
Primary Voltage
6/6.3/6.6/10/10.5/11/20/35kv
Secondary Voltage
11/10.5/6.3/6/3.15/0.4kv
Insulation Level
C, H, F
Frequency
50/60Hz
Impedance
4%/6%
Connection Symbol
Dyn11/Yyn0
Tapping Range
±2*2.5%/±5%
Standard
IEC60076
Core Material
Silicon Steel
Cooling Way
an/Af
Working Temperature
-20ºC~60ºC
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000
Production Capacity
10000 Pieces/Year

Product Description

Pioneering the way as the first company in China to achieve the remarkable feat of passing the prestigious KEMA E2, C2, F1 tests for cast resin transformers.

CEEG's innovative cast resin dry-type transformers are distinguished by numerous proprietary patents, expertly engineered to meet the demands of indoor environments requiring stringent fire and explosion resistance, alongside exceptional durability against high temperatures and moisture. Perfectly suited for venues such as bustling commercial centers, densely populated residential areas, critical care hospitals, and robust industrial factories, these transformers also excel in outdoor applications within challenging conditions like those found in petrochemical enterprises. Delivering exceptional performance, these transformers exhibit outstanding resilience to seasonal load variations and can effortlessly endure overload situations, making them a top choice for encapsulated distribution systems.

Working Environment
These transformers are designed to perform reliably across a broad range of temperatures: -20ºC to 60ºC.

Insulation

Material

expoxy resin class H / class C Nomex paper

Structure

 

HV coil is multi layer sectional cylinder structure, LV coil is foil with longitudinal air chamber structure.

Reliability

Insulation class

H(180ºC)

Tem. rise of coil

125K(normal 100K)

Over-load capacity

continuously 120%

Cooling method

AN/AF

 Environmental Protection

Noise

Low

Recycling

easy recycling and low pollution



Product Features

1. Unmatched reliability with minimal loss, exceptional low partial discharge (maintained below 5PC), whisper-quiet operation, and superior heat dissipation, capable of enduring 150% overload when subjected to forced air cooling conditions.

2. Exceptional moisture resistance, ensuring flawless operation even in environments with 100% humidity.

3. Prioritizes safety with fire protection features and pollution-free operation, making it ideal for direct installation in load centers.

4. Integrated with an advanced temperature protection and control system to ensure optimal performance.

5. Designed for ease of use, the transformer is maintenance-free, simple to install, and ensures economical operation with low overall costs.



Export Case
Our partnership with LafargeHolcim began in 2014, providing them with CEEG SCB and SC series cast resin dry-type transformers. These units have been successfully installed and are operating efficiently in LafargeHolcim's cement plants located in Nigeria, the Philippines, and Cameroon.


Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
 

Class F Insulation SCB10-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB10-315/10

4

880

3470

1.0

55

660 x 660

SCB10-400/10

4

980

3990

1.0

55

660 x 660

SCB10-500/10

4

1160

4880

1.0

57

660 x 660

SCB10-630/10

4

1340

5880

0.85

57

820 x 820

SCB10-630/10

6

1300

5960

0.85

57

820 x 820

SCB10-800/10

6

1520

6960

0.85

58

820 x 820

SCB10-1000/10

6

1770

8130

0.85

58

820 x 820

SCB10-1250/10

6

2090

9690

0.85

60

820 x 820

SCB10-1600/10

6

2450

11700

0.85

60

820 x 820

SCB10-2000/10

6

3050

14400

0.70

62

820 x 820

SCB10-2500/10

6

3600

17100

0.70

62

820 x 820

 

Class F Insulation SCB11-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB11-315/10

4

790

3470

1.0

55

660 x 660

SCB11-400/10

4

880

3990

1.0

55

660 x 660

SCB11-500/10

4

1040

4880

1.0

57

660 x 660

SCB11-630/10

4

1200

5880

0.85

57

820 x 820

SCB11-630/10

6

1170

5960

0.85

57

820 x 820

SCB11-800/10

6

1360

6960

0.85

58

820 x 820

SCB11-1000/10

6

1590

8130

0.85

58

820 x 820

SCB11-1250/10

6

1880

9690

0.85

60

820 x 820

SCB11-1600/10

6

2200

11700

0.85

60

820 x 820

SCB11-2000/10

6

2740

14400

0.70

62

820 x 820

SCB11-2500/10

6

3240

17100

0.70

62

820 x 820

 

Class F Insulation SCB12-315~2500/10

Rated High Voltage:10(10.5,11,6.6,6.3,6)kV

Rated Low Voltage:0.4kV

Vector Group: Dyn11or Yyn0

Insulation Level: Ll 75 AC 35 / Ll AC 3; Tap Range:±2*2.5%

Model

UK%

P0(W)

Pk(120ºC)(W)

I0%

LPA(AN)dB

Gauge m x n (mm)

SCB12-315/10

4

705

3470

1.0

55

660 x 660

SCB12-400/10

4

785

3990

1.0

55

660 x 660

SCB12-500/10

4

930

4880

1.0

57

660 x 660

SCB12-630/10

4

1070

5880

0.85

57

820 x 820

SCB12-630/10

6

1040

5960

0.85

57

820 x 820

SCB12-800/10

6

1210

6960

0.85

58

820 x 820

SCB12-1000/10

6

1410

8130

0.85

58

820 x 820

SCB12-1250/10

6

1670

9690

0.85

60

820 x 820

SCB12-1600/10

6

1960

11700

0.85

60

820 x 820

SCB12-2000/10

6

2440

14400

0.70

62

820 x 820

SCB12-2500/10

6

2880

17100

0.70

62

820 x 820



Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload CapacityDurable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload CapacityDurable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

Equipment:


Advanced Slitting Line

Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

Precision Shearing Line
Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

HEDRICH State-of-the-Art Vacuum Casting Tank
Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

High-Efficiency Curing Oven
Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

Innovative Foil Winding Technology
Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity

Comprehensive Testing Center
Durable Cast Resin Dry Type Transformer with 100-25000kVA and Strong Overload Capacity
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now