110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 12 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (30)
  • 110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
  • 110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
  • 110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
  • 110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
  • 110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
  • 110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
Find Similar Products

Basic Info.

Model NO.
SFSZ11
Usage
Power Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Ceeg
Rated Capacity
6300-420000kVA
Primary Voltage
110/121/132/220kv
Secondary Voltage
6.3/6.6/10.5/11/35/38.5/63/66/69kv
Frequency
50/60Hz
Impedance
8%~24%
Connection Symbol
Ynyn0/Ynd11/D11
Tapping Range
±2*2.5%/±8*1.25%
Transport Package
International Wooden Case or According to Client′s
Trademark
CEEG
Origin
Jiangsu, China
HS Code
8504349000

Product Description

CEEG has over 30 years of experience in the power transmission and distribution sector and is now an intelligent transmission and distribution solutions provider. We hold 52 patents in oil-filled transformers, and our oil-immersed transformers have maintained strong sales for three decades. We operate an in-house high-voltage test station, which is essential for our 220kV and 230kV transformers.

 

In 2023, our CNAS (China National Accreditation Service for Conformity Assessment) testing center was officially unveiled. This indicates that we can carry out testing services according to international accreditation standards (ISO/IEC17025). The testing data and reports issued by the testing center within the scope of accreditation can use the China National Laboratory Accreditation Service (CNAS) and the International Laboratory Accreditation Cooperation (ILAC) logos, which are recognized by more than 100 countries and regions including the United States, the United Kingdom, Germany, France, the Netherlands, Japan, etc. that have signed mutual recognition agreements.


Product Features of 110kv Oil Transformer

1. Low Loss: No-load loss is reduced by 20% compared to national standards, and load loss is reduced by 5%.

2. Low Noise: Natural cooling noise levels are below 60dB, 3 to 5dB lower than national standards.

3. Low Partial Discharge: Dust-free operations keep partial discharge levels below 100pC.

4. Short Circuit Resistance: Passed sudden short circuit tests at the National Transformer Testing Center.

5. Leakage-Free: All sealing components are made from acrylic in one piece and undergo fluorescence, positive pressure, and negative pressure leak tests.


110kv

110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer

SFSZ11  - XXX /XX

S/N Symbol Meaning
1 S Three phases
2 F Air-cooling
3 S Three windings
4 Z On load tap changing
5 11 Symbol of Performance level (11,13)
6 xxx Rated capacity,kVA
7 xx Voltage grade of HV winding,kV

 

S(F)11/13-110kV 6300-90000kVA Dual Winding Power Transformer

Capacity

kVa

Voltage Ratio & Tapping Range Vector Group No Load Loss Load Loss No Load Current Impedance
HV Tapping Range LV 11 13
6300

110

115

121

±2X2.5%       

6.3

6.6

  10.5       

 YNd11  7.4  5.92  35  0.62   10.5
8000  8.9 7.12  42  0.62
10000 10.5 8.4  50  0.58 
12500 12.4  9.92  59  0.58
16000  15.0  12.0  73  0.54 
 20000 17.6  14.08  88  0.54 
 25000 20.8  16.64  104  0.5
31500 24.6 19.68 123 0.48
40000 29.4 23.52 148 0.45
50000 35.2 28.16 175 0.42
63000 41.6 33.28 208 0.38
90000 54.4 43.52 272 0.8 12-14


SS(F)11/13-110kV 6300-63000kVA Three Winding Power Transformer

Capacity

kVa

Voltage Ratio & Tapping Range

Vector

Group

No Load Loss

Load

Loss

No Load Current Impedance
HV MV LV 11 13 Stepup Setdown
6300

110±2X2.5% 

115±2X2.5% 

121±2X2.5% 

36

37

38.5    

6.3

6.6

10.5   

21

 YNyn0

d11

8.9 7.12 44 0.66

HV-MV

17.5-18.5

HV-LV

10.5

MV-LV

6.5  

HV-MV

10.5-18.5

HV-LV

18-19

MV-LV

6.5

8000 10.6 8.48 53 0.62
10000 12.6 10.08 62 0.59
12500 14.7 11.76 74 0.56
16000  17.9 14.32 90 0.53
 20000 21.1 16.88 106 0.52
 25000 24.6 19.68 126 0.48
31500 29.4 23.52 149 0.48
40000 34.8 27.84 179 0.44
50000 41.6 33.28 213 0.41
63000 49.2 39.26 256 0.40

110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
 

Product Features of 220kv Oil Transformer

1.  No Partial Discharge: Actual measured partial discharge is less than 50pC, lower than the background noise.

 

2.  High Efficiency and Low Loss: Innovative core and coil design, along with leakage magnetic flux control technology, effectively reduces additional and stray losses.

 

3.  Low Noise: Actual measured noise is below 60dB, significantly better than the national standard noise levels.

 

4.  Intelligent Design: Meets the operational requirements of intelligent substations.

 

5.  Maintenance-Free Design: Comprehensive design includes air self-cooling methods, fiberglass dry-type bushings, and metal corrugated internal oil-type conservators, free of routine on-site maintenance, making it suitable for unattended substations.

 

6.  Compact Structure Design: Adopt the industrial advanced 220kV end inlet method, resulting in a compact overall structure, facilitating easier transportation and on-site installation.

 

7.  Strong Short Circuit Resistance: Utilizes foreign short-circuit mechanical force verification procedures and ensures all assembly stages of the transformer body meet design requirements.

 

8.  Over 40-Year Design Life: Unique high-temperature-resistant hybrid insulation system based on temperature field simulation analysis, ensuring all transformer components have the same design life as the transformer itself.

 

9.  Passes All Routine and Type Tests at Once: The transformer's overall performance reaches advanced domestic levels.


220kv 
 
110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
230kv
 
110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
Testing Process
110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer
110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer110kv 121kv 132kv 220kv 230kv Oil-Immersed High Voltage Power Transformer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now